Resource FZC’s Marine Cable - LKSM Offering:

Fire-resistant, armoured power and control cable. For fixed installation in most areas, and on open deck in ships and offshore units. If the cable is exposed to direct sunlight, protective covering or cable with black outer sheath is recommended.

LKSM-FRHF 0.6/1kV

Conductor
Stranded copper conductor 1.0-10 mm², IEC 60228 Class 2
Stranded copper conductor 16-300 mm², IEC 60228 Class 5
Insulation
Mica tape + XLPE, IEC 60092-360
Cabling
Cores twisted together. Fillers or dummy cores included in select sizes based on product specifications to obtain symmetrical and round construction, covered by separator tape
Bedding
Lapped tape
Armour
Copper wire braid, coverage > 90%, IEC 60092-350
Rip cord
For conductors ≥ 16 mm²
Sheath
Polyolefin SHF1, IEC 60092-360
Standard colour orange, other colours on request

Fire-resistant, armoured power and control cable. For fixed installation in most areas, and on open deck in ships and offshore units. If the cable is exposed to direct sunlight, a protective covering or cable with a black outer sheath is recommended.

Core identification
Colour code for 1…4 core cables, number code for 5…37 core cables
Marine Type Approvals
ABS, BV, CCS, CRS, DNV,KR, LR, RINA
Rated voltage
AC 0,6/1kV (1.2 kV)
DC 0.9/1.5 kV (if voltage to earth does not exceed 0.9 kV)
Fire performance
IEC 60332-1-2
IEC 60332-3-22
Fire-resistant
IEC 60331-1 / IEC 60331-2 (180 min)
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Min. installation temperature
-15 °C
Operating temperature
-40 – 80 °C fixed installation
Max. Conductor temperature
90 °C

LKSM-FRHF 250V

Conductor
Stranded copper conductor 1.0-10 mm², IEC 60228 Class 2
Stranded copper conductor 16-300 mm², IEC 60228 Class 5
Insulation
Mica tape + XLPE, IEC 60092-360
Cabling
Cores twisted together. Fillers or dummy cores included in select sizes based on product specifications to obtain symmetrical and round construction, covered by separator tape
Bedding
Lapped tape
Armour
Copper wire braid, coverage > 90%, IEC 60092-350
Rip cord
For conductors ≥ 16 mm²
Sheath
Polyolefin SHF1, IEC 60092-360
Standard colour orange, other colours on request

Fire-resistant, armoured power and control cable. For fixed installation in most areas, and on open deck in ships and offshore units. If the cable is exposed to direct sunlight, a protective covering or cable with a black outer sheath is recommended.

Core identification
Colour code for 1…4 core cables, number code for 5…37 core cables
Marine Type Approvals
ABS, BV, CCS, CRS, DNV,KR, LR, RINA
Rated voltage
AC 0,6/1kV (1.2 kV)
DC 0.9/1.5 kV (if voltage to earth does not exceed 0.9 kV)
Fire performance
IEC 60332-1-2
IEC 60332-3-22
Fire-resistant
IEC 60331-1 / IEC 60331-2 (180 min)
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Min. installation temperature
-15 °C
Operating temperature
-40 – 80 °C fixed installation
Max. Conductor temperature
90 °C

LKSM-FRHF+WSR/WJR 0.6/1kV

Conductor
Stranded copper conductor 1.0-10 mm², IEC 60228 Class 2
Stranded copper conductor 16-300 mm², IEC 60228 Class 5
Insulation
Special grade Mica tape + XLPE, IEC 60092-360
Cabling
Cores twisted together. Fillers or dummy cores are included in select sizes based on product specifications to obtain symmetrical and round construction, covered by separator tape
Armour
Copper wire braid, coverage > 90%, IEC 60092-350
Tinned copper wire braid on request
Ripcord
For conductors ≥ 16 mm²
Sheath
Polyolefin SHF1, IEC 60092-360
Standard colour orange, other colours on request

Fire-resistant + Water Spray Resistant and/or Water Jet Resistant armoured power and control cable. For fixed installation in most areas, and on open deck in ships and offshore units. Especially intended to ensure availability of all critical transportation-, comfort- and safety systems, i.e. to meet the concepts of; Orderly Evacuation (3 hours burning time) and Safe Return to Port (Fire test with simultaneous Water Spray / Water Jet + mechanical shocks) to simulate firefighting conditions. If the cable is exposed to direct sunlight, protective covering or cable with black outer sheath is recommended.

Cable Type
CABLE TYPES: Cable Ø≤20 mm LKSM-FRHF+WSR Cable Ø>20 mm LKSM-FRHF+WJR
Core identification
Colour code for 1…4 core cables, number code for 5…37 core cables
Marine Type Approvals
DNV, LR, RINA
Rated voltage
AC 0,6/1kV (1.2 kV)
DC 0.9/1.5 kV (if the voltage to earth does not exceed 0.9 kV)
Fire performance
IEC 60332-1-2
IEC 60332-3-22
Fire- and water spray resistant
IEC 60331-2 + EN 50200 Annex E(180 min)
Fire- and water-jet-resistant
IEC 60331-1 + BS 8491 (180 min)
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
Min. installation temperature
-15 °C
Operating temperature
-40 – 80 °C fixed installation
Max. Conductor temperature
90 °C